nMotion
S21
Stepper Motor Controller · by
nChip
⚠️ Please use
Chrome
or
Edge
(89+) over HTTPS or localhost.
www.nchip.in ↗
🌙 Dark
Not Connected
🎮 Live Control
📝 Sequence Setup
⚙️ Advanced Settings
🔌 Connection
Connect Device
Disconnect
💡 Indicator LEDs
Temperature
Normal
Sleep
Idle
🌡️ Motor Temperature
--
°C
Sensor mounted on motor body
Cool:
45
°C
Stop:
55
°C
📊 Status
State
Idle
Enabled
No
Direction
CW
Speed
80
Mode
—
Fading
No
Runtime
0 min
🎮 Manual Control
Speed:
80
µs (1–1000)
1
5
10
20
50
100
Direction
↻ Forward
↺ Reverse
Timed Run (seconds)
▶ Run
Runs at the set speed for exactly this many seconds.
Continuous
▶ START
⏹ STOP
Enable
Disable
Reverse
⏱ Runtime Limit
Limit
360 min
Elapsed
0 min
➕ Add Step
Step Type
Forward (CW)
Reverse (CCW)
Forward + Fade
Reverse + Fade
Wait / Delay
Repeat from start
Stop sequence
Speed (µs) 1–1000
Duration (seconds)
Delay (milliseconds)
➕ Add Step
🌡️ Temperature Safety
Stop motor when temperature reaches (°C)
Resume when temperature drops below (°C)
Apply Temperature
✨ Fade Effect
Enable Fade In/Out
Enabled
Disabled
Fade Duration (ms) 100–5000
Apply Fade
⏱ Runtime Limit
Motor auto-stop after (minutes)
Apply Runtime
📝 Sequence Steps (max 20)
🔄 Refresh
#
Step
Speed
Time
Delay
No steps yet
💾 Save Settings
Stores sequence, temperature, runtime & fade in device memory
Clear
Save & Exit
▶️ Run Saved Sequence
Starts the stored sequence immediately
Run
Stop
🎛 Hardware Overrides
Bypass On/Off Switch
Disabled (Use Switch)
Enabled (Ignore Switch)
If enabled, the motor ignores the physical switch and runs continuously via web control.
Start Motor on Power On
Disabled
Enabled
If enabled, the motor starts automatically when the device powers up.
💡 LED Indications
Temperature LED Indication
Enabled (Normal)
Disabled (Off)
Sleep LED Indication
Enabled (Normal)
Disabled (Off)
🌡️ Safety Overrides
Temperature Control
Enabled (Safety Active)
Disabled (Ignore Temp)
If disabled, the motor will keep running regardless of the temperature sensor reading.
⚙️ Motor Config
Motor Pulse per Rev (PPR)
400
800
1600
3200
6400
8000
12800
25600 (Default)
51200
Change this to match your DM542 DIP switch settings. Lower PPR = Faster motor speed.
Apply Advanced Settings
📋 Activity Log
Clear